SCI和EI收录∣中国化工学会会刊

Chin.J.Chem.Eng. ›› 2012, Vol. 20 ›› Issue (4): 665-672.

• SEPARATION SCIENCE AND ENGINEERING • Previous Articles     Next Articles

HPLC Analysis of Egg Yolk Phosphatidylcholine by Evaporative Light Scattering Detector

ZHOU Jing, HU Xianmei, WANG Tianxin, LIANG Hao, YUAN Qipeng   

  1. State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China
  • Received:2011-03-30 Revised:2011-09-24 Online:2012-09-15 Published:2012-08-28

HPLC Analysis of Egg Yolk Phosphatidylcholine by Evaporative Light Scattering Detector

周婧, 胡仙妹, 王田心, 梁浩, 袁其朋   

  1. State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China
  • 通讯作者: YUAN Qipeng, E-mail:yuanqp@mail.buct.edu.cn

Abstract: Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids were based on the American Oil Chemists' Society(AOCS) Official Method Ja7b-91,in which n-hexane/2-propanol/acetate buffer was used as the mobile phase.In order to achieve desired results,gradient elu-tion or buffer solution was used,which made the detection process more complicated.Moreover,water or buffer solution could affect the silica gel column both on its lifespan and the separation efficiency significantly.In this study,different mobile phase and detector were used to simplify EYPC analyzing process instead of using water within the mobile phase.The optimized HPLC operating conditions are as follows:pure methanol as a mobile phase,flow rate of 1.0 ml·min-1,silica gel column(250 mm×4.6 mm,5 μm,Inertsil GLTM),column temperature 30℃ and low temperature evaporative light scattering detector(40℃,0.35 MPa) as used.Under this optimal condition,the linear relative coefficient of the standard curve is 0.998 and the recovery was in the range of 96.83%-101.58% with a relative standard deviation of 1.79%(n=6).

Key words: egg yolk phosphatidylcholine, high performance liquid chromatography, evaporative light scattering detector

摘要: Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids were based on the American Oil Chemists' Society(AOCS) Official Method Ja7b-91,in which n-hexane/2-propanol/acetate buffer was used as the mobile phase.In order to achieve desired results,gradient elu-tion or buffer solution was used,which made the detection process more complicated.Moreover,water or buffer solution could affect the silica gel column both on its lifespan and the separation efficiency significantly.In this study,different mobile phase and detector were used to simplify EYPC analyzing process instead of using water within the mobile phase.The optimized HPLC operating conditions are as follows:pure methanol as a mobile phase,flow rate of 1.0 ml·min-1,silica gel column(250 mm×4.6 mm,5 μm,Inertsil GLTM),column temperature 30℃ and low temperature evaporative light scattering detector(40℃,0.35 MPa) as used.Under this optimal condition,the linear relative coefficient of the standard curve is 0.998 and the recovery was in the range of 96.83%-101.58% with a relative standard deviation of 1.79%(n=6).

关键词: egg yolk phosphatidylcholine, high performance liquid chromatography, evaporative light scattering detector