SCI和EI收录∣中国化工学会会刊

›› 2014, Vol. 22 ›› Issue (10): 1087-1091.DOI: 10.1016/j.cjche.2013.05.002

• SEPARATION SCIENCE AND ENGINEERING • Previous Articles     Next Articles

Experimental Investigation onHeat Exchange and Separation Performance of an Annular Structured Internal Heat-integrated Distillation Column

Lianghua Xu, Dawei Chen, Binghai Yan, Xigang Yuan   

  1. State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China
  • Received:2013-01-06 Revised:2013-05-20 Online:2014-12-01 Published:2014-10-28
  • Supported by:
    Supported by the National Key Basic Research Program of China (2012CB720500).

Experimental Investigation onHeat Exchange and Separation Performance of an Annular Structured Internal Heat-integrated Distillation Column

Lianghua Xu, Dawei Chen, Binghai Yan, Xigang Yuan   

  1. State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China
  • 通讯作者: Xigang Yuan
  • 基金资助:
    Supported by the National Key Basic Research Program of China (2012CB720500).

Abstract: In this paper heat exchange coefficient and separation efficiency of an annular structured internal heat-integrated distillation column (HIDiC) were experimentally measured. About 50% heat of the inner column could be transferred to the outer column. The overall heat exchange coefficient decreased with an increase in pressure ratio of the inner column and the outer column, but was little affected by the F-factor. The increase of the pressure ratio decreased obviously the separation efficiency of the outer column but had little effect on that of the inner column.

Key words: Internal heat-integrated distillation column, Overall heat exchange coefficient, Separation efficiency

摘要: In this paper heat exchange coefficient and separation efficiency of an annular structured internal heat-integrated distillation column (HIDiC) were experimentally measured. About 50% heat of the inner column could be transferred to the outer column. The overall heat exchange coefficient decreased with an increase in pressure ratio of the inner column and the outer column, but was little affected by the F-factor. The increase of the pressure ratio decreased obviously the separation efficiency of the outer column but had little effect on that of the inner column.

关键词: Internal heat-integrated distillation column, Overall heat exchange coefficient, Separation efficiency