SCI和EI收录∣中国化工学会会刊

›› 2011, Vol. 19 ›› Issue (5): 779-783.

• SELECTED PAPERS FROM THE 4TH NATIONAL CONFERENCE ON MASS TRANSFER AND SEPARATION ENGINEERING AND IN HONOUR OF PROF. K. T. YU (YU GUOCONG) • Previous Articles     Next Articles

Pressure Drop Measurements on Distillation Columns

T.J. Cai, M. R. Resetarits   

  1. Fractionation Research, Inc., 424 S. Squires St, Suite 200, Stillwater, OK 74074, USA
  • Received:2011-06-10 Revised:2011-08-25 Online:2011-10-28 Published:2011-10-28

Pressure Drop Measurements on Distillation Columns

T. J. Cai, M. R. Resetarits   

  1. Fractionation Research, Inc., 424 S. Squires St, Suite 200, Stillwater, OK 74074, USA
  • 通讯作者: T.J. Cai,E-mail:cai@fri.org

Abstract: Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sec-tional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is con-firmed by a fundamental fluid dynamics analysis.

Key words: distillation, tray, packing, pressure drop, hydraulics

摘要: Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sec-tional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is con-firmed by a fundamental fluid dynamics analysis.

关键词: distillation, tray, packing, pressure drop, hydraulics