SCI和EI收录∣中国化工学会会刊

Chinese Journal of Chemical Engineering ›› 2018, Vol. 26 ›› Issue (4): 723-730.DOI: 10.1016/j.cjche.2017.08.004

• Separation Science and Engineering • 上一篇    下一篇

Design aspect of a novel L-shaped pulsed column for liquid-liquid extraction applications: Energy consumption and the characteristics velocity concept

Pouria Amani1, Elham Mohammadi2, Sahar Akhgar2   

  1. 1 School of Chemical Engineering, College of Engineering, University of Tehran, P. O. Box:11155-4563, Tehran, Iran;
    2 Chemical Engineering Department, Tarbiat Modares University, P. O. Box:14115-143, Tehran, Iran
  • 收稿日期:2017-03-23 修回日期:2017-03-23 出版日期:2018-04-28 发布日期:2018-05-19
  • 通讯作者: Pouria Amani,E-mail address:pouria.amani@ut.ac.ir

Design aspect of a novel L-shaped pulsed column for liquid-liquid extraction applications: Energy consumption and the characteristics velocity concept

Pouria Amani1, Elham Mohammadi2, Sahar Akhgar2   

  1. 1 School of Chemical Engineering, College of Engineering, University of Tehran, P. O. Box:11155-4563, Tehran, Iran;
    2 Chemical Engineering Department, Tarbiat Modares University, P. O. Box:14115-143, Tehran, Iran
  • Received:2017-03-23 Revised:2017-03-23 Online:2018-04-28 Published:2018-05-19
  • Contact: Pouria Amani,E-mail address:pouria.amani@ut.ac.ir

摘要: This article deals with the evaluation of the consumption of energy for a steady state solvent extraction in a novel L-shaped pulsed sieve-plate column, which is highly required for design and optimization of the periodic flow processes for industrial applications. In this regard, a comprehensive evaluation on the energy consumption in case of a pulsed flow for three different chemical systems is conducted and besides the influence of pulsation intensity, the effect of geometrical parameters including the plate spacing and the plate free area is investigated as well. Moreover, the concept of characteristic velocity models at flooding points is evaluated with respect to the variation of pressure drop along the column at different operational conditions.

关键词: Solvent extraction, Pulsed plate column, Pressure drop, Energy consumption, Pulsed flow, Characteristic velocity

Abstract: This article deals with the evaluation of the consumption of energy for a steady state solvent extraction in a novel L-shaped pulsed sieve-plate column, which is highly required for design and optimization of the periodic flow processes for industrial applications. In this regard, a comprehensive evaluation on the energy consumption in case of a pulsed flow for three different chemical systems is conducted and besides the influence of pulsation intensity, the effect of geometrical parameters including the plate spacing and the plate free area is investigated as well. Moreover, the concept of characteristic velocity models at flooding points is evaluated with respect to the variation of pressure drop along the column at different operational conditions.

Key words: Solvent extraction, Pulsed plate column, Pressure drop, Energy consumption, Pulsed flow, Characteristic velocity