[1] P. Promvonge, S. Skullong, S. Kwankaomeng, C. Thiangpong, Heat transfer in square duct fitted diagonally with angle-finned tape-Part 1: Experimental study, Int. Commun. Heat Mass Transfer 39 (2012) 617-624. [2] P. Promvonge, S. Skullong, S. Kwankaomeng, C. Thiangpong, Heat transfer in square duct fitted diagonallywith angle-finned tape-Part 2: Numerical study, Int. Commun. Heat Mass Transfer 39 (2012) 625-633. [3] P. Promvonge, W. Changcharoen, S. Kwankaomeng, C. Thianpong, Numerical heat transfer study of turbulent square-duct flow through inline V-shaped discrete ribs, Int. Commun. Heat Mass Transfer 38 (2011) 1392-1399. [4] P. Promvonge, S. Sripattanapipat, S. Tamna, S. Kwankaomeng, C. Thianpong, Numerical investigation of laminar heat transfer in a square channel with 45°inclined baffles, Int. Commun. Heat Mass Transfer 37 (2010) 170-177. [5] P. Promvonge,W. Jedsadaratanachai, S. Kwankaomeng, Numerical study of laminar flow and heat transfer in square channel with 30°inline angled baffle turbulators, Appl. Therm. Eng. 30 (11-12) (2010) 1292-1303. [6] P. Promvonge, S. Sripattanapipat, S. Kwankaomeng, Laminar periodic flow and heat transfer in square channel with 45°inline baffles on two oppositewalls, Int. J. Therm. Sci. 49 (2010) 963-975. [7] S. Kwankaomeng, P. Promvonge, Numerical prediction on laminar heat transfer in square duct with 30°angled baffle on one wall, Int. Commun. Heat Mass Transfer 37 (2010) 857-866. [8] S. Eiamsa-ard, N. Koolnapadol, P. Promvonge, Heat transfer behavior in a square duct with tandem wire coil element insert, Chin. J. Chem. Eng. 20 (5) (2012) 863-869. [9] S. Eiamsa-ard, V. Kongkaitpaiboon, K. Nanan, Thermohydraulics of turbulent flow through heat exchanger tubes fitted with circular-rings and twisted tapes, Chin. J. Chem. Eng. 21 (6) (2013) 585-593. [10] S. Eiamsa-ard, C. Thianpong, P. Eiamsa-ard, P. Promvonge, Convective heat transfer in a circular tube with short-length twisted tape insert, Int. Commun. Heat Mass Transfer 36 (2009) 365-371. [11] S. Eiamsa-ard, P. Promvonge, Heat transfer characteristics in a tube fitted with helical screw-tape with/without core-rod inserts, Int. Commun. Heat Mass Transfer 34 (2) (2007) 176-185. [12] S. Eiamsa-ard, P. Promvonge, Influence of double-sided delta-wing tape insert with alternate-axes on flow and heat transfer characteristics in a heat exchanger tube, Chin. J. Chem. Eng. 19 (3) (2011) 410-423. [13] P. Promvonge, T. Chompookham, S. Kwankaomeng, C. Thianpong, Enhanced heat transfer in a triangular ribbed channel with longitudinal vortex generators, Energy Convers. Manag. 51 (6) (2010) 1242-1249. [14] T. Chompookham, C. Thianpong, S. Kwankaomeng, P. Promvonge, Heat transfer augmentation in a wedge-ribbed channel using winglet vortex generators, Int. Commun. Heat Mass Transfer 37 (2010) 163-169. [15] C. Thianpong, T. Chompookham, S. Skullong, P. Promvonge, Thermal characterization of turbulent flow in a channel with isosceles triangular ribs, Int. Commun. Heat Mass Transfer 36 (2009) 712-717. [16] S. Skullong, P. Promvonge, Experimental investigation on turbulent convection in solar air heater channel fitted with delta winglet wortex generator, Chin. J. Chem. Eng. 22 (1) (2014) 1-10. [17] V. Sri Harsha, S.V. Prabhu, R.P. Vedula, Influence of rib height on the local heat transfer distribution and pressure drop in a square channel with 90°continuous and 60°Vbroken ribs, Appl. Therm. Eng. 29 (11-12) (2009) 2444-2459. [18] A. Gupta, V. Sri Harsha, S.V. Prabhu, R.P. Vedula, Local heat transfer distribution in a square channel with 90°continuous, 90°saw tooth profiled and 60°broken ribs, Exp. Thermal Fluid Sci. 32 (2008) 997-1010. [19] G. Tanda, Heat transfer in rectangular channelswith transverse and V-shaped broken ribs, Int. J. Heat Mass Transfer 47 (2004) 229-243. [20] P.R. Chandra, C.R. Alexander, J.C.Han, Heat transfer and friction behaviors in rectangular channels with varying number of ribbed walls, Int. J. Heat Mass Transfer 46 (2003) 481-495. [21] A. Murata, S. Mochizuki, Comparison between laminar and turbulent heat transfer in a stationary square duct with transverse or angled rib turbulators, Int. J. Heat Mass Transfer 44 (2001) 1127-1141. [22] J.C. Han, Y.M. Zhang, C.P. Lee, Influence of surface heat flux ratio on heat transfer augmentation in square channels with parallel, crossed, and V-shaped angled ribs, ASME J. Turbomach. 114 (1992) 872-880. [23] J.C. Han, Y.M. Zhang, C.P. Lee, Augmented heat transfer in square channels with parallel, crossed and V-shaped angled ribs, ASME Heat Transfer 113 (1991) 590-596. [24] S.C. Lau, R.T. Kukreja, R.D. McMillin, Effects of V-shaped rib arrays on turbulent heat transfer and friction of fully developed flow in a square channel, Int. J. Heat Mass Transfer 34 (7) (1991) 1605-1616. [25] ANSI/ASME, Measurement uncertainty, PTC 19, Part I, 1-19851986. [26] R.L. Webb, Performance evaluation criteria for use of enhanced heat transfer surfaces in heat exchanger design, Int. J. Heat Mass Transfer 24 (1981) 715-726. [27] F.P. Incropera, P.D. Witt, T.L. Bergman, A.S. Lavine, Fundamentals of Heat and Mass Transfer, John-Wiley & Sons, 2006. |