Turbulent Heat Transfer and Pressure Drop in Tube Fitted with Square-cut Twisted Tape

P. Murugesan1, K. Mayilsamy2, S. Suresh3   

  1. 1. Department of Mechanical Engineering, K. S. Rangasamy College of Technology, Tiruchengode-637215, India;
    2. Department of Mechanical Engineering, Institute of Road and Transport Technology, Erode-638316, India;
    3. Department of Mechanical Engineering, National Institute of Technology, Tiruchirappalli-620015, India
  • 收稿日期:2010-02-24 修回日期:2010-07-02 出版日期:2010-08-28 发布日期:2010-08-28
  • 通讯作者: P. Murugesan, E-mail:pmksrct@gmail.com

Turbulent Heat Transfer and Pressure Drop in Tube Fitted with Square-cut Twisted Tape

P. Murugesan1, K. Mayilsamy2, S. Suresh3   

  1. 1. Department of Mechanical Engineering, K. S. Rangasamy College of Technology, Tiruchengode-637215, India;
    2. Department of Mechanical Engineering, Institute of Road and Transport Technology, Erode-638316, India;
    3. Department of Mechanical Engineering, National Institute of Technology, Tiruchirappalli-620015, India
  • Received:2010-02-24 Revised:2010-07-02 Online:2010-08-28 Published:2010-08-28

摘要: Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes (STT) and plain twisted tapes (PTT) are investigated experimentally using the water as working fluid.The tapes (STT and PTT) have three twist ratios(y=2.0,4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000.The experimental results reveal that heat transfer rate,friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance.Over the range considered,the Nusselt number,friction factor and thermal enhancement factor in a tube with STT are respectively,1.03 to 1.14,1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT.An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT.

关键词: heat transfer enhancement, friction factor, plain twisted tape, square-cut twisted tape, secondary flow

Abstract: Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes (STT) and plain twisted tapes (PTT) are investigated experimentally using the water as working fluid.The tapes (STT and PTT) have three twist ratios(y=2.0,4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000.The experimental results reveal that heat transfer rate,friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance.Over the range considered,the Nusselt number,friction factor and thermal enhancement factor in a tube with STT are respectively,1.03 to 1.14,1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT.An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT.

Key words: heat transfer enhancement, friction factor, plain twisted tape, square-cut twisted tape, secondary flow